Вакумні системи для взяття крові

Vacuum systems for blood sampling TUBE WITHOUT FILLER The inner wall of the tube with a special treatment makes it similar to the wall of blood vesselshuman.The smooth inner surface reduces the risk of sample hemolysis.T…

Вакумні системи для взяття крові

Vacuum systems for blood sampling

 

\"TUBE
TUBE WITHOUT FILLER

The inner wall of the tube with a special treatment makes it similar to the wall of blood vessels
human.
The smooth inner surface reduces the risk of sample hemolysis.
The use of a unique composition of plastic eliminates the problem of blood sticking to the wall
test tubes.
The preservation of the original blood composition is guaranteed as much as possible, which makes the test result more accurate.
! FOR BEST RESULTS WE RECOMMEND WAIT 1 HOUR,
AND THEN CENTRIFUGE FOR 10 MINUTES AT 1100•1300G!

 

 

>>
HIGH QUALITY TUBE
WITH COLLECTION ACTIVATOR

In 2012, a patent was obtained for the coagulation activator.
The unique composition prevents blood from sticking to the wall of the test tube.
The use of a special coagulation activator ensures maximum output of high-quality serum.
Thanks to the unique patented technology, the problem of cell breakage is solved and
recessive hemolysis in the process of rapid coagulation.
High-quality coagulation activator reduces the time of complete clotting to 10 min, blood
folds completely, while fibrin threads rarely appear.
 
! FOR BEST RESULTS WE RECOMMEND INVERTING THE TUBE 8 TIMES, WAIT 20 MINUTES AND THEN CENTRIFUGE FOR 10 MINUTES AT 1100•1300G !

 

 

\"\"
HIGH QUALITY TUBE
WITH SEPARATION GEL

In 2012, a patent was obtained for the separating gel.
The technology of thermal stability ensures the quality of the serum, storage at a low temperature and the possibility of freezing the sample.
Inert, high-quality separating gel does not create physical or chemical interference in routine experiments.
High stability, no "oil drops" after storage and centrifugation.
The unique patented technology allows you to avoid the release of small molecules on the surface of the serum, contamination of samples or blocking of the needle.
 
! FOR BEST RESULTS, WE RECOMMEND INVERTING THE TUBE 8 TIMES, WAIT 20 MINUTES AND THEN CENTRIFUGE FOR 5•10 MINUTES AT 1300•2000G !

 

 

\"TUBE
TUBE WITH LITHIUM HEPARIN
TUBE WITH SODIUM HEPARIN

The modern technology of micro-spraying provides a quick effect
anticoagulation of heparin on blood samples, which allows to quickly obtain
high-quality plasma samples.
The original tube can be tested on the equipment and stored,
it  helps  the  laboratory  save  costs,  reduce  processing  time  and 
to improve the quality of the entire work process.
 
! FOR BEST RESULTS WE RECOMMEND WAIT 1 HOUR AND THEN CENTRIFUGE FOR 10 MINUTES AT 1100•1300G !
\"TUBE

 

 

\"TUBE
TUBE WITHOUT FILLER

The material of the inner wall of the tube is polypropylene, the material of the outer tube is
PET, a double barrier reduces the permeability of water and air of a plastic tube,
ensures the accuracy of the blood coagulation test.
Unique stress membrane treatment for inner wall avoids coagulation
mechanism from activation through the material of the test tube.
The use of patented technology prevents the activation of blood coagulation factors and platelets, provides conditions for an accurate result and immutability
prothrombin time and APTT time.
 
! FOR BEST RESULTS, WE RECOMMEND INVERTING THE TUBE 8 TIMES AND THEN CENTRIFUGE FOR 5•10 MINUTES AT 2200G!

 

 

\"TUBE
TUBE WITH K2/K3 EDTA

Features: A unique process of rapid atomization of the filler provides
excellent mixing of the filler with the blood sample.
Advanced technology for world-class production, long-term and efficient
maintains the composition and amount of filler throughout the shelf life.
The unique bionic treatment of the inner walls allows for effective support
stability of platelet activity.
The special treatment of the walls of the test tubes makes them very smooth and completely eliminates the impact
charge.
Strict control technology eliminates the impact of microparticle contamination on
test result.
The latest anti-microcoagulation and anti-microagglutination technology.

 

 

\"TUBE
TUBE FOR MEASURING GLUCOSE IN PLASMA

The complex anticoagulation system avoids the risk of external coagulation and hemolyzation.
The unique composition of the filler significantly reduces the glycolysis of erythrocytes.
The latest technologies ensure the stability of blood samples with glucose for a long time.
Clinical trials have shown that blood glucose is stable for 5 days at
storage of samples at 2-8 °С
! FOR BEST RESULTS, WE RECOMMEND INVERTING THE TUBE 8 TIMES AND THEN CENTRIFUGE FOR 5•10 MINUTES AT 1000•1200G!

 

 

>>
SHOE TUBE

0.129 mol/l Sodium-Citrate buffer system for anticoagulation of blood samples.
The fully closed ESR tube can be used directly on the
dynamic ESR analyzer is more convenient and safe.
Special treatment effectively avoids boiling of the filler and also supports
vacuum level.

 

 

\"TUBE
TUBE WITH SEPARATION GEL K2 EDTA

Production in completely cleaned conditions minimizes the possible impact of contamination on the test results.
The inner wall is treated with diethylricarbonate (DEPC), the finished products are sterilized by Co60, the level of sterility: 10-6, completely eliminates the effect of the RNA enzyme on the test.
The use of a unique filler technology does not affect the activity of the Taq enzyme used in nucleic acid testing, and effectively eliminates the interference of hemoglobin in erythrocytes on the test result

 

 

Microtubes for taking capillary blood

Material: plastic. Shelf life: 2 years. Volume: 0.1-0.5 ml. Size: 8x45 mm.

\"\"

 


Download PDF booklet

 

Request a quote

Request a quote

Leave a request and our manager will prepare an individual offer for your laboratory.

We’ll call you back

Leave your number — our manager will call you back shortly.